Xi'An PPE MAX Co., Ltd brings over six decades of safety excellence since 1956, specializing in Class 0 Insulating Gloves designed for maximum protection up to 1,000V AC and 1,500V DC applications. Our enterprise-grade gloves feature a proof test voltage of 5,000V AC, distinguished by red labels under ASTM D120 standards. With Type I common elastic development giving 1.02mm thickness for predominant adroitness, our gloves convey zero-failure unwavering quality for electrical laborers around the world. We serve businesses from EV fabricating to sun based establishments, guaranteeing your group returns domestic securely each day..

Our gloves are specialized electrical security hardware built to secure specialists from stun dangers whereas keeping up remarkable ability. These gloves give basic security for energized circuits up to 1,000 Volts AC and 1,500 Volts DC.
Unlike higher-rated classes, these gloves bridge the hole between low-voltage control work and dispersion upkeep. They address key industry challenges: adjusting dielectric quality with manual adroitness for complicated assignments, relieving circular segment streak dangers, and guaranteeing compliance with OSHA 29 CFR 1910.137 and NFPA 70E regulations.
The particular ruddy labeling framework makes a difference specialists rapidly distinguish the redress assurance level. This color coding takes after strict ASTM and IEC guidelines, anticipating perilous mix-ups in high-pressure work environments.

|
Parameter |
Specification |
|
Maximum Use Voltage |
1,000V AC / 1,500V DC |
|
Proof Test Voltage |
5,000V AC / 20,000V DC |
|
Label Color |
Red (ASTM D120/IEC 60903) |
|
Material Type |
Type I (Natural Rubber) / Type II (EPDM) |
|
Thickness |
1.02mm (0.040 inches) |
|
Length Options |
11", 14", 16" inches |
|
Cuff Styles |
Straight, Bell, Contour |
|
Standards Compliance |
ASTM D120, IEC 60903, OSHA 29 CFR 1910.137 |

Our gloves experience thorough verification testing at voltages five times higher than their working voltage. This guarantees dependable assurance indeed beneath extraordinary conditions.
The 1.02mm thickness gives amazing material affectability. You can handle little components, clasp, and accuracy devices without compromising safety.
Choose between Sort I characteristic elastic for greatest flexibility or Sort II manufactured elastic for upgraded ozone and UV resistance in open air applications.
Multiple length and sleeve alternatives suit different work situations and clothing prerequisites whereas avoiding electrical tracking.

With over 65 a long time of fabricating involvement, our gloves provide zero-failure execution in life-critical situations. We test each bunch to ensure consistency.
Our Class 0 Insulating Gloves work successfully over different voltage ranges, making them cost-effective for different electrical applications.
High pliable quality and cut resistance guarantee long benefit life. When matched with calfskin defenders, they withstand unforgiving mechanical conditions.
Full compliance with worldwide security benchmarks gives you certainty amid reviews and audits
EV professionals depend on our gloves for battery pack support on 400V-800V frameworks. The predominant adroitness permits exact control of Battery Management System connectors while protecting against DC arc flash hazards.
Linemen utilize these gloves for hot work on auxiliary dissemination lines, savvy meter establishments, and transformer associations up to 600V. They give basic security amid live wire maintenance.
Solar installers working with string voltages up to 1,000V DC believe our Type II gloves. The ozone-resistant material withstands UV introduction in sun based cultivate situations whereas keeping up electrical integrity.
Perfect for Lockout/Tagout confirmation and investigating on 480V-600V Motor Control Centers. They protect workers during panel maintenance and breaker operations.

Since 1956, PPE MAX has ensured laborers around the world. Our involvement interprets into items you can believe with your life.
Every team member uses our equipment. We test our products ourselves because we believe in what we create.
Our vision expands to each corner of the world, but we treat each client as family. Your security is our individual commitment.
We continually make strides our plans based on real-world criticism from electrical professionals.

Our Class 0 Insulating Gloves meet or exceed:

We give direction on appropriate testing plans and methods to keep up glove integrity.
Our building group offers application back and measuring suggestions for your particular needs.
Flexible substitution planning guarantees your group continuously has appropriately tried hardware available.
Q: How often should Class 0 gloves be tested?
A: Test every six months or according to your company's safety protocols and local regulations.
Q: Can I use these gloves for higher voltages?
A: No. Never exceed the 1,000V AC rating. Use appropriate higher-class gloves for greater voltages.
Q: Do I need leather protectors?
A: Yes. Always wear leather protector gloves to prevent mechanical damage to the rubber insulation.
Q: What's the difference between Type I and Type II?
A: Type I offers superior elasticity, while Type II provides better resistance to environmental factors like ozone and UV radiation.
Q: How do I know if my gloves are damaged?
A: Inspect for cuts, punctures, or deterioration before each use. When in doubt, remove from service immediately.